| Please refer to users manual for more detailed and up-to-date description of specification. |
|
| AC Watt (50 or 60 Hz, PF 0.5 to 1. CT = 1, Accuracy of Readings) Model 21 (0 to 50A), Model 23 (0 to 100A) |
| Range |
Resolution |
Accuracy 21 (0 - 30A) Accuracy 23 (0 - 60A) |
Accuracy 21 (30 - 50A) Accuracy 23 (60 - 100A) |
| 0.000 – 9.999 W |
0.001 W |
±1% ± 0.02 W |
±2% of VA ± 5dgts |
| 10.00 – 99.99 W |
0.01 W |
±1% ± 0.2 W |
±2% of VA ± 5dgts |
| 100.0 – 999.9 W |
0.1 W |
±1% ± 0.2 W |
±2% of VA ± 5dgts |
| 1.000 – 9.999 KW |
0.001 KW |
±1% ± 0.02 KW |
±2% of VA ± 5dgts |
| 10.00 – 99.99 KW |
0.01 KW |
±1% ± 0.2 KW |
±2% of VA ± 5dgts |
| 100.0 – 999.9 KW |
0.1 KW |
±1% ± 0.2 KW |
±2% of VA ± 5dgts |
| 1000 – 9999 KW |
1 KW |
±1% ± 2 KW |
±2% of VA ± 5dgts |
|
| AC Current (50 or 60 Hz, True RMS) |
| Range (Model 19,21) |
Range (Model 23) |
Resolution |
Accuracy of Readings |
| 0.30 – 60.00mA |
0.30 – 60.00mA |
0.01mA |
±0.5% ± 5dgts |
| 60.0 – 600.0mA |
60.0 – 600.0mA |
0.1mA |
±0.5% ± 5dgts |
| 0.030 – 3.000 A |
0.030 – 9.999 A |
0.001 A |
±0.5% ± 5dgts |
| 3.00 – 30.00 A |
10.00 – 60.00 A |
0.01 A |
±0.5% ± 5dgts |
| 30.00 – 50.00 A |
6 0.00 – 99.99 A |
0.01 A |
±1.0% ± 5dgts |
|
| AC Voltage (50 or 60 Hz, True RMS) |
| Range |
Resolution |
Accuracy of R. |
Range |
Resolution |
Accuracy of R. |
| 3V – 250V |
0.1 V |
±0.5% ± 5dgts |
250V – 600V |
0.1 V |
±0.5% ± 5dgts |
|
| Harmonics of AC Voltage in % and Magnitude (1 to 99th order) |
| Range |
Resolution |
Accuracy in % |
Resolution |
Accuracy in Magnitude |
| 50V – 600V |
0.1 % |
±0.5% |
0.1 V |
±0.5% ± 0.5V |
|
| Harmonics of ACA in % Percentage and Magnitude (1 to 99th order) |
| Range (Model 19, 21) |
Range (Model 23) |
Res. |
Accuracy (%) |
Res. |
Accuracy of R. |
| 10.00 – 60.00mA |
10.00 – 60.00mA |
0.1 % |
±0.5% |
0.01mA |
±0.5% ± 0.1mA |
| 60.0 – 600.0mA |
60.0 – 600.0mA |
0.1 % |
±0.5% |
0.1mA |
±0.5% ± 1mA |
| 0.5 – 3.000 A |
0.5 – 9.999 A |
0.1 % |
±0.5% |
0.001 A |
±0.5% ± 0.01 A |
| 3.00 – 30.00 A |
10.00 – 60.00 A |
0.1 % |
±0.5% |
0.01 A |
±0.5% ± 0.1 A |
| 30.00 – 60.00 A |
6 0.00 – 99.99 A |
0.1 % |
±1.0% |
0.01 A |
±1.0% ± 0.1 A |
|
| Power Factor and Phase Angle (PF, Φ ,Model 21 and 23) |
| Range (PF) |
Resolution |
Accuracy |
Range (Φ) |
Resolution |
Accuracy |
| 0.000 – 1.000 |
0.001 |
± 1° |
-180° to 180° (0 ° to 360 ° ) |
0.1° |
± 1° |
|
| Total Harmonic Distortion (THD-F, 1 to 99th order) Crest Factor (C.F., Accuracy of Readings) |
| Range |
Resolution |
Accuracy of R. |
Range |
Resolution |
Accuracy of R. |
| 0.0 – 999.9 % |
0.1% |
± 0.5% ± 5 digits |
1.00 – 99.99 |
0.01 |
± 5% ± 30 digits |
|
| Conductor Size |
30mm (approx.) |
| Battery Type |
1.5V SUM-3 x 2 |
| Display |
4+2+2 digits LCD |
| Power Consumption |
5mA (approx.) |
| Auto-Power-Off |
30 minutes |
| No. Of Samples/Period |
512 (V & A), 256 (W) |
| LCD update rate |
2 times / sec. |
| Weight |
200g (battery included) |
| Operating Temperature |
-10 ° C to 50° C |
| Operating Humidity |
< 85% relative |
| Storage Temperature |
-20° C to 60° C |
| Storage Humidity |
: < 75% relative |
| Dimension |
210 (L) x 62 (W) x 35.6mm (H), 8.3" (L) x 2.5" (W) x 1.4" (H) |
| Accessories |
test leads, Carrying bag x 1, Users manual x 1 |
| Option |
|
|